+91-9971016943 info@kamalmedtech.com

“Innovative Stent Design with proven blend of anti-proliferative Drug sirolimus & Bioresorbable Polymers, Contributing to exceptional Acute & Long term Performance”

Kamal Medtech Building

KAMAL MEDTECH: A PIONEER IN STENT MANUFACTURING IN INDIA

Kamal Medtech is one of the leading cardiac stents manufacturers in India which has developed pathbreaking innovative coronary stents and healthcare solutions to the cardiology consultants & patients for improving clinical consequences for various cardiac ailments.  We at Kamal Medtech is one of the few coronary stent manufacturing companies in India who is known for creating world-class cardiac stent products with the highest standard of quality and clinical significance. We meticulously design, develop, manufacture and market made in India coronary stents that aid in less invasive cardiac therapy. Our stents stand out in comparison with other Indian stents in terms of quality and innovation. We provide cutting edge and innovative cardiac stents for the treatment of chronic heart disease at an extremely affordable price for the common man.

From our inception, we have made significant headway which has placed us as a key manufacturer of coronary stents in India, and generated new levels of efficiency ensuring our continued competence to serve patients with modest pricing.

We are now paving our knowledge base to cover other cardiovascular illnesses and developing state-of-the-art technologies to meet physician and patients’ expectations.  Our vision is to make Kamal Medtech a trusted brand and a market leader for physicians and people at large.

India is soon going to be the most populous country in the world and with the current lifestyle with excessive smoking, alcohol consumption and sedentary habits, the number of patients with chronic heart disease is expected to rise exponentially in near future. Keeping the trend in mind, we, at Kamal Medtech aim to develop a wide range of Indian stents that helps us address people with these rising risks more effectively and provide affordable solutions.

From bare metal stents to Everolimus eluting coronary stents, we have traversed significant mile in expanding the skyline of cardiac stents for coronary angioplasty and we obstinately continue our quest of revolution in the field of Interventional Cardiology.

Our made in India cardiac stent is just one way of complimenting Atmanirbhar Bharat Abhiyan, a vision of the Prime Minister of India Narendra Modi which translates to ‘self-reliant’ or ‘self-sufficient’ ‘self-sustaining’ and ‘self-generating’ India in terms of providing cure to millions who undergo coronary angioplasty every year.

 

 

Flexibility like never Before!

The optimum and meticulously arranged cells and links which offers flexibility of next level, enabling the stent to navigate through the most tortuous coronary arteries.

CONTROLLED DRUG RELEASE RESULTING SUPERIOR CLINICAL OUTCOMES

Siroflex Plus has proven drug release kinetics. Initial burst of Sirolimus followed by sustained release upto 40 days. Bioresorbable Polymers completely degrade by hydrolysis & enzymatic degradation which is eventually excreted from the body in the form of CO2 and H2O.

STENT SPECIFICATION

Design Open cell stent design
Material Cobalt Chromium (CoCr) L605
Length (mm) 8, 13, 16, 20, 24, 28, 32, 36, 40, 43 & 47
Diameter (mm) 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50
Strut Thickness 65 μm
Strut Width 70 μm
Connectors Width 50 μm
Foreshortening Nearly Zero
Recoil ≤ 5 %
Crossing Profile Nearly 1.00 mm
Min. Guidewire Diameter 0.014”
Min. Guiding Catheter I.D. 5 Fr Compatible
Radial Strength Excellent
Flexibility Excellent

Superior Coating Technology

Drug polymer blend is coated on polished stent surface with highly specialised spray coating machines resulting in drug coated stent with unmatched features.

Superior Coating Technology

Drug polymer blend is coated on polished stent surface with highly specialised spray coating machines resulting in drug coated stent with unmatched features.

ORDERING INFORMATION

  Stent Length (mm)
Diameter (mm) 8 13 16 20 24 28 32 36 40 43 47
2.00 SF20008 SF20013 SF20016 SF20020 SF20024 SF20028 SF20032 SF20036 SF20040 SF20043 SF20047
2.25 SF22508 SF22513 SF22516 SF22520 SF22524 SF22528 SF22532 SF22536 SF22540 SF22543 SF22547
2.50 SF25008 SF25013 SF25016 SF25020 SF25024 SF25028 SF25032 SF25036 SF25040 SF25043 SF25047
2.75 SF27508 SF27513 SF27516 SF27520 SF27524 SF27528 SF27532 SF27536 SF27540 SF27543 SF27547
3.00 SF30008 SF30013 SF30016 SF30020 SF30024 SF30028 SF30032 SF30036 SF30040 SF30043 SF30047
3.50 SF35008 SF35013 SF35016 SF35020 SF35024 SF35028 SF35032 SF35036 SF35040 SF35043 SF35047
4.00 SF40008 SF40013 SF40016 SF40020 SF40024 SF40028 SF40032 SF40036 SF40040 SF40043 SF40047
4.50 SF45008 SF45013 SF45016 SF45020 SF45024 SF45028 SF45032 SF45036 SF45040 SF45043 SF45047

© 2020 Kamal Medtech. All Rights Reserved. Please read the Legal Notice for further details. Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Kamal Medtech, its subsidiaries or affiliates. No use of any Kamal Medtech trademark, trade name, or trade dress in this site may be made without the prior written authorization of Kamal Medtech, except to identify the product or services of the company.